MEDICAL APPARATUS

STERILIZERS & AUTOCLAVES 

Powerful disinfection tools for any dental office

SciCan Autoclaves

SciCan was originally a distributor of German medical equipment in the late 1950’s, but eventually branched out to begin manufacturing its own SciCan Statim autoclaves. SciCan’s solutions are used in everything from the largest mutli-office dental practices down to the smallest clinic. Their products are designed with a high level of infection control knowledge behind them, which is evident in both the design and features of the Statim Autoclaves.

STATCLAVETM G4 Chamber Autoclave

Cutting Edge Sterilisation

With the reliability and trust you’ve come to expect from STATIM, the STATCLAVE G4 is designed to deliver speed, capacity and efficiency to your practice. STATCLAVE is a chamber autoclave that incorporates both pre-sterilization vacuum to improve steam penetration and post-sterilization vacuum to improve drying. Its 11” chamber and vacuum-assisted closed-door drying efficiently delivers sterilised and dried wrapped instruments.

  • Fast

STATCLAVE can efficiently sterilize and dry wrapped instrument loads.

  • Dry

Closed-door drying and vacuum technology results in perfectly dried instruments every time.

  • G4 Technology

SciCan’s G4 equipment can connect and send information to your smart devices or computer so you can have cycle data, instructions, and maintenance notifications at your fingertips.

  • Capacity

    STATCLAVE’s 11” chamber can sterilize up to 4 full-size cassettes and 4 exam cassettes or 20 pouches.

  • Versatile

    STATCLAVE offers a number of filling & draining options, including easily accessible and cleanable top reservoirs, front manual fill and a rear automatic fill option that can be connected to the VistaPure water filtration system for automated filling.

  • Gentle

    Fresh water is used in every cycle, reducing the buildup of oils and debris.

Scican Bravo Chamber Autoclave

The Perfect Blend of Speed and Capacity

The BRAVO fractionated vacuum chamber autoclave continues the SciCan tradition of being at the forefront of innovation and technology. BRAVO incorporates both pre-vac (to remove air) and post-vac (to help drying) cycles to ensure perfect steam penetration for any load.

BRAVO is true to the STATIM reputation for speed, providing rapid cycles for all types of instrument loads. Available in 17 or 21 Liter Chamber Capacity.

  • Speed

The BRAVO line of chamber autoclaves is one of the fastest on the market today. BRAVO offers a perfect blend of speed and chamber capacity coupled with our drying technology to ensure your daily output of reprocessed instruments cannot be rivaled.

  • Dryness

With closed door drying and the Dri-Tec drying system, the BRAVO gives you lightning fast & consistent dry loads every time to allow more loads to be processed daily.

  • Versatility

The BRAVO offers numerous sterilization cycles with a wide array of parameters.

This allows the user to choose the appropriate cycle for the load, be it wrapped or unwrapped.

  • Ease of use

The BRAVO can be initiated by a single button. Once the BRAVO has been properly loaded, the user can choose from one of four pre-set cycles as defined by the user.

  • Data Storage

For any future guidelines, the BRAVO 21V (220V) saves all the data from each cycle. The integrated front USB port allows cycle data to be stored digitally, making record keeping simple and efficient. The same feature is available as an external accessory for model BRAVO17V (120V).

Sterilisation Cycle Description Chart

INSTRUMENTS WASHERS

Automated Instrument Washing the first step in the sterilization process

1 CYCLE TIMES REPRESENT 220V UNITS. CYCLE TIMES FOR 110V UNITS ESTIMATED UP TO 7 MINUTES LONGER.

2 HOLLOW INSTRUMENTS TYPE “A” AND “B” ACCORDING TO EN 13060:2004 (IE. HANDPIECES, PHACO INSTRUMENTS, TROCARS, RIGID SCOPES, ETC.)

  • Under counter steri-center installation, but can also be a freestanding unit

  • G4 web portal interface includes data storage, service logs and remote access capabilities

  • Validated cycles to ensure repeatable washing performance

  • Ten 8” x 11” IMS cassette capacity

  • USB port for data storage

  • Robust stainless steel exterior includes pump for liquid detergent

  • Web based documentation software included – no installation required

  • Active hot air drying

  • Manufactured in Canada

Connect

The HYDRIM G4 is capable of communicating directly with service personnel or anyone you choose.

Should the HYDRIM G4 ever need attention, diagnostic information can be sent via email to pre-selected dealer service reps, significantly reducing down time.

 

Protect

The HYDRIM G4 supports verifiable processes that are PIN protected with user-defined IDs so that staff members can be required to authorize a cycle.

This encourages extra attention to process and creates a safer environment for both staff and patient.

 

Collect

With each cycle, information must be stored to protect your office and your patients. The integrated data logger store all cycle information for the lifetime of the unit. A USB port allows for the manual retrieval of cycle history. The 10/100 Base-T Ethernet connection puts your PC in direct contact with your HYDRIM G4 and the RS232 serial printer port allows you to connect with an external

printer.

 

Hydrim Meets The Internet

A high-resolution, 65K color touch screen offers a vivid display of messages, current cycle information and customizable colors all with extraordinary clarity. Fully adjustable contrast levels let you optimize the screen to the lighting in your steri-center, and it’s 2.5-inch by 3-inch dimensions allow easy viewing of cycle information.

Benefits

HYDRIM L110w can process 2,500 instruments in a 10-hour day

Under counter steri-center installation, but can also be a freestanding unit

G4 web portal interface includes data storage, service logs and remote access capabilities

Validated cycles to ensure repeatable washing performance

Ten 8” x 11” IMS cassette capacity

HIP Cleaning solution is stored in the unit, so no extra storage space requirements

Vivid color touch screen

USB port for data storage

Robust stainless steel exterior

Includes pump for liquid detergent

Web based documentation software included – no installation required

Active hot air drying

* Actual cycle times are dependant on several variables including incoming water temperature and/or pressure, electrical supply and in-line water filtration systems